Sampling & Data Quality

Intermediate14 min

Educational content in scientific-draft form; a specialist should review it before it is adopted as an academic reference. No measurement or performance result that was not actually obtained is shown here.

Module: Sensors & Data Acquisition

Learning objectives

  • Choosing a sampling rate
  • Detecting quality problems

The sampling rate determines what can be seen in the signal. According to the Nyquist–Shannon theorem the rate must exceed twice the highest frequency that matters in the signal, otherwise a distortion called aliasing appears. A slowly changing room temperature needs a low rate, but machine vibration needs a far higher one.

Common quality problems: missing values due to connectivity loss, outliers caused by a reading error rather than a real phenomenon, gradual drift over time, and electrical noise. Always record the timestamp with each reading.

Before training any model: plot the data, compute the share of missing values and examine the distribution. Much "model failure" is data failure.

In the sensor simulator lab you can generate a synthetic signal with deliberately added noise and anomalies to try these phenomena. Remember that it is synthetic data, not real measurements.

Simulations and labs run inside your browser. Nothing you enter and none of the conversations is stored on the server. Privacy policy